Part Number Description and Details Illustration and Dimensions Drawing Terminal Diagram Circuit Diagram Voltage Operating Voltage Nominal-Max. Contact Material T87 Maximum N.O. Resistive Load Amps-Life Cycles Other Loads See Group# in Load Table
0 332 002 150 SPST, dual contact (1) S6 12V - 16V STO 75A - 100,000 13
0 332 002 156 SPST, with parallel and series diodes (1) S3 12V - 15V Silver Nickel 75A - 100,000 14
0 332 002 250 SPST, pre-contact (1) S2 24V - 32V Silver Nickel 50A - 100,000 15
0 332 002 256 SPST, with parallel and series diodes (1) S3 24V - 30V Silver Nickel 50A - 100,000 16

POWER RELAYS
Part Number Pull-In Voltage Drop-out Voltage Resistance Nominal Operating Current
No resistor or with diode With resistor
0 332 002 150 <8.0V 1.5 - 4.0V 46 ± 5 ohm N/A 290mA
0 332 002 156 <8.0V 1.5 - 4.0V 46 ± 5 ohm N/A 290mA
0 332 002 250 <8.0V 1.0 - 8.0V 130 ± 10 ohm N/A 200mA
0 332 002 256 <8.0V 1.0 - 8.0V 130 ± 10 ohm N/A 200mA

LOAD AND LIFE CYCLE TEST DATA FOR POWER RELAYS
Contact testing conditions Load Switching Cycle
For STO (Silver Tin Oxide) contacts:   Life cycles tested at 23°C Resistive 2 Sec ON, 2 Sec OFF
For Silver Nickel (AgNi20) contacts:   Life cycles tested at 23°C Motor 5 Sec ON, 5 Sec OFF

POWER RELAY LOAD TABLE
Load Group Voltage Contact Position Resistive Load Motor Load
Continuous Life Cycles In Rush Duration Continuous Life Cycles
13 12V NO 75A 100,000 400A 1 Sec 60A 40,000
14 12V NO 75A 100,000 250A 1 Sec 60A 40,000
15 24V NO 75A 100,000 200A 1 Sec 40A 40,000
16 24V NO 50A 100,000 150A 1 Sec 40A 40,000

POWER RELAYS - CHARACTERISTICS
Operating CharacteristicsMechanical CharacteristicsEnvironmental Characteristics
Response Time   <15mSRandom Vibration Test 10Hz - 1000Hz for 3hOperating Temperature -40°C to + 85°C
Contact Voltage Drop - New, at 10A < 100mV (24V, at 10 A) - After life test < 200mVSine Wave Vibration Test 10Hz - 200Hz, 2.5 G's for 3hHumidity Test 95% for 14 days
Drop Test - All Sides 1 meterSalt Spray-All Sides 144 hours
Mechanical Life    >1,000,000Cover Retention Force > 300NDust Test 8 hours
Coil Inductance   <200mH(12V) <500mH(24V)Cover Crush Force >220 N